DEFINITY ECS Release 8.2
Administrator’s Guide
555-233-506
Issue 1
April 2000
Introduction to the DEFINITY system
32Receiving notification in an emergency
2
2. In the dialed string field, type 5555.
This is the number that end-users dial to reach emergency services.
3. In the Total Min and Max fields, type
4.
In this example, the user must dial all 4 digits for the call to be treated as an
emergency call.
4. In the Route Pattern field, type
1.
In this example, we use route pattern 1 for local calls.
5. In the Call Type field, type
alrt.
This identifies the dialed string 5555 as one that activates emergency
notification.
6. Press
ENTER to save your changes.
Now set up the attendant console to receive emergency notification.
7. Type
change attendant 1 and press RETURN.
The Attendant Console
screen appears.
8. In the feature button area, assign a
crss-alert button.
9. Press
ENTER to save your changes.
10. Assign a
crss-alert button to each security guard’s phone.
You cannot assign this button to a soft key. See ‘‘
Adding feature buttons’’
on page 57 for more information.
ARS DIGIT ANALYSIS TABLE
Location: all Percent Full: 6
Dialed Total Route Call Node ANI
String Min Max Pattern Type Num Reqd
5555_____________ 4_ 4_ 1____ alrt ___ n
_________________ __ __ _____ ____ ___ n
_________________ __ __ _____ ____ ___ n
_________________ __ __ _____ ____ ___ n
_________________ __ __ _____ ____ ___ n
_________________ __ __ _____ ____ ___ n
_________________ __ __ _____ ____ ___ n
_________________ __ __ _____ ____ ___ n
_________________ __ __ _____ ____ ___ n
_________________ __ __ _____ ____ ___ n
_________________ __ __ _____ ____ ___ n
_________________ __ __ _____ ____ ___ n
_________________ __ __ _____ ____ ___ n
_________________ __ __ _____ ____ ___ n
_________________ __ __ _____ ____ ___ n
_________________ __ __ _____ ____ ___ n