DEFINITY ECS Release 8.2
Administrator’s Guide
555-233-506
Issue 1
April 2000
Screen reference
937System Parameters Customer-Options
17
Mode Code Interface
Allows you to use the Mode Code Voice Mail System Interface to connect the
switch over a DTMF interface to I
NTUITY AUDIX or other vendors’ voice mail
systems.
Multifrequency Signaling
Provides for a screen of number signaling used between the switch and the central
office.
Multimedia Appl. Server Interface (MASI)
Allows users of the Multimedia Communications Exchange (MMCX) to take
advantage of certain DEFINITY ECS telephony features.
Multimedia Call Handling (Basic)
Allows administration of desktop video-conferencing systems as data modules
associated with DEFINITY ECS voice stations in a multimedia complex. Users
can dial one number to reach either endpoint (voice or data) in the complex. Also
provides support for IP SoftPhones.
Multimedia Call Handling (Enhanced)
Allows a multifunction phone to control a multimedia call like a standard voice
call. Also provides support for IP SoftPhones.
Personal Station Access (PSA)
Provides basic telecommuting package capability for Personal Station Access.
Also provides support for IP SoftPhones.
PNC Duplication
This field only appears on DEFINITY ECS G3r. If set to
y, the Enable Operation
of PNC (Port Network Connectivity) Duplication field appears on the System
Parameters Duplication screen. The Enable Operation of PNC Duplication field is
set with the Enable Operation of SPE (Switch Processing Element) Duplication
field to provide non-standard reliability levels (high, critical, or ATM PNC
Network Duplication).
Processor and System MSP
Allows the customer administrator or technician to maintain processor and system
circuit packs.