Lucent Technologies 8.2 Security Camera User Manual


  Open as PDF
of 1707
 
DEFINITY ECS Release 8.2
Administrator’s Guide
555-233-506
Issue 1
April 2000
Screen reference
743ISDN trunk group
17
ISDN-BRI Trunk Circuit Pack — This screen is required if using
ISDN-BRI trunk interfaces. Assign all fields as required.
DS1 Circuit Pack — This screen is required if using ISDN-PRI interfaces.
DS1 (T1) Circuit Pack
Assign all fields as required. For Facility Associated Signaling, up
to 23 ports are available for administration as trunk members in an
associated ISDN-PRI trunk group. The 24th port is used as a
signaling channel. For Non-Facility Associated Signaling, all 24
ports may be used on certain DS1 circuit packs. The D-channel
signaling function for these packs must be provided by a designated
DS1 pack on its 24th channel.
E1 Circuit Pack
Assign all fields as required. For Facility Associated Signaling, up
to 30 ports are available for administration as trunk members in an
associated ISDN-PRI trunk group. Port number 16 is used as a
signaling channel.
Maintenance-Related System-Parameters — Use this screen only for a
TN778. Set the Packet Bus Maint field to
y.
ISDN Trunk Group — Enter information in all the fields except the trunk
group members. When using ISDN-PRI interfaces, enter the members after
you establish the signaling links.
Signaling Group — This screen is required if ISDN-PRI interfaces are
used. Complete all fields. This screen identifies groups of ISDN-PRI DS1
interface B-channels for which a given D-channel (or D-channel pair) will
carry the associated signaling information (supports the Facility and
Non-Facility Associated Signaling feature). Each DS1 board that is
required to have a D-channel must be in a different signaling group by itself
(unless D-channel backup is needed, in which case a second DS1 is
administered as a backup D-channel). You are not required to select a
channel for a trunk group, but if you do, you must have already defined the
trunk group as type ISDN.
NOTE:
The following three screens, Processor Interface Data Module,
Communication Interface Links, and Communication Processor
Channel Assignment are used only to support the ISDN-PRI
interfaces using PI TN765.