DEFINITY ECS Release 8.2
Administrator’s Guide
555-233-506
Issue 1
April 2000
Managing multimedia calling
241Multimedia Call Handling
9
Screen 15. Data Module screen (Page 1 of 2)
Screen 16. Data Module screen (Page 2 of 2)
Type — Set the data module type to 7500 or WCBRI.
Multimedia This field appears on the data module screen only if MM is
set to yes on the System-Parameters Customer Options screen. Enter Y to
enable this data module to be multimedia compliant.
MM Complex Voice Ext: (display only) — This field contains the number
of the associated telephone in the complex. This is a display-only field, and
is blank until you enter the data module extension in the Station screen MM
Complex Data Ext field. Once you have done that, these two extensions are
associated as two parts of a multimedia complex.
XID and MIM Support — Valid entries are y (default) and n. These fields
must be set to n.
Page 1 of 2
DATA MODULE
Data Extension: 65001 Name: ___________________________
Type: 7500_______ COS: 1_ Multimedia? y
Port: _____ COR: 1_ MM Complex Voice Ext: 67434
ABBREVIATED DIALING
List1: ____________
SPECIAL DIALING OPTION: hot-line
HOT LINE DESTINATION
Abbreviated Dialing Dial Code (From above list): _
CIRCUIT SWITCHED DATA ATTRIBUTES (used for modem pooling)
Default Duplex: full Default Mode: async Default Speed: 1200_
DATA MODULE CAPABILITIES
Default ITC: restricted Default Data Application? M2_A
Page 2 of 2
DATA MODULE
BRI LINK/MAINTENANCE PARAMETERS
XID? n Fixed TEI? n TEI: ___
MIM Support? n