DEFINITY ECS Release 8.2
Administrator’s Guide
555-233-506
Issue 1
April 2000
Screen reference
1016Trunk Group
17
Outgoing Seizure (msec)
Appears when the Country field is
15, the Direction field is outgoing or two-way,
and the Trunk Type field is
2-wire-ac, 2-wire-dc, or 3-wire. This timer is sent
only to the TN2199 circuit pack.
Incoming Incomplete Dial Alarm (sec)
Only the TN436 (all), TN459 (all), TN464C (or later), TN767, TN2140, TN2146,
TN2184, TN2199, and TN2242 circuit packs use this timer.
Outgoing Last Digit (sec)
This field is only administrable if the Trunk Signaling Type field is
dis or cont
and the trunk group Direction field is
two-way or outgoing. Only TN497 and
TN2140 ports receive this timer.
Glare
This field is only administrable if the Trunk Signaling Type field is
cont and the
trunk group Direction field is
two-way or outgoing. Only TN2140 ports receive
this timer.
Valid entries Usage
20
to 2550 in
increments of
10
Enter the duration of the outgoing seizure signal.
Valid entries Usage
1
to 255 in
increments of 1
Enter the maximum acceptable interval between an incoming
seizure and receipt of all digits. Intervals greater than this limit
generate an inline error.
Valid entries Usage
1
to 40 Enter the maximum time that the switch will wait for the next
digit dialed. After the timer expires, no more digits are
accepted by the circuit pack.
Valid entries Usage
40
to 100 in
increments of
10
Enter the minimum acceptable interval (in msec) between the
moment your switch sends an outgoing seizure and the moment
it receives a seizure acknowledgment. If acknowledgment is
received before the timer expires, glare is assumed.